站内搜索
|
详细信息 Product Name: Lightning Arrester, Surge Arrester, Pararrayos, Parafoudre 3-132kv, 10ka Model NO.: Y5C-11 Brand: Oeipower Jingguan Certification: Xihari Material: ZnO Shape: Round Operation Voltage: High Voltage Size: Meidum Application: AC/DC System Installation: Pole Line Structure: Zinc Oxide Arrester Type: Distribution 12: Kv 24: Kv 36: Kv Trademark: OEIpower Transport Package: Cartons Pallets Wooden Case Specification: IEC IEEE Origin: China Nanyang HS Code: 85354000 Product Description metaL OXIDE SURGE ARRESTERPolymer housed for outdoor applicationFeaturesBetter Electrical performance & reliabilityEase of Installation-Light weight & smaller sizeBetter Operating conditionsExplosion & shatter proof & less mechanicaldamage to nearby equipmentsBetter performance in polluted environmentVandalism resistantFree from Moisture ingressHigher safetyHigher mechanical strengthInsensitive to UV radiationHigh resistance to Ozone & CoronaExcellent Tracking resistancePerformance DataSystem VoltageRated Voltage (kV):0.1-275Nominal discharge current (kA)High current capability (4/10us) kAEnergy Class :Energy absorption Capability kJ/kVShort Circuit (Pressure relief) kA:40Standard in accordance with:IEC60099-4Porcelain housed for outdoor applicationFor protection of transformer & switchgear.Highly non-linear MOV.Explosion Proof - Pressure Relief Design.High energy handling capacity.Glazed brown Porcelain Housing.Corrosion proof Aluminum alloy metal flange.Suitable for Ambient -400C to +550C.manufactures effective surge protection device with the modern technology of highly non-linear ZincOxide Varistor blocks and thus diverts natural lightning surge and switching surge to earth and simultaneously clip offany follow on current. Our station class arresters are designed to provide maximum safety to personnel and sub-stationequipment even at the enormous short circuit duty. Research and Development is an ongoing process at Elektroliteswith the active collaboration of experts in the industry.ConSTRUCTION & OPERATING PRINCIPLELightning Arrestors11kVNo.DETAILUNITSDATAType11kV gapless type metal oxide surgearrester - Distribution class1.Nominal system voltagekV112.Highest system voltagekV123.Basic Insulation Level (BIL)kV953. Ratings and type of surge arrester4.Specification to which surge arrester compliesIEC60099-45.Rated voltage of surge arresterkV106.Nominal, 8/20 µs, discharge current rating ofsurge arresterkA107.Maximum continuous operating voltage ofsurge arresterkV7.38.Gapless or gapped type metal-oxide surgearresterGapless9.Material of insulationHigh temperature vulcanised siliconrubber10.Rated frequency of surge arresterHz5011.Design altitude of surge arrester (above sealevel)m1 400m12.Design ambient temperature of surge arresteroC-1 to4013.Specific creepage distance of surge arrester.mm/kV25Automatic earth lead disconnectorsrequirements14.Automatic earth lead disconnectors to be fittedYes/NoYES15.Corrosion protection of metal and alloy parts:galvanising specification and/or stainless steel gradeTo SABS 763, 316Tests16.Previous type test results/certificate to beprovided with bidYes/NoYes17.Routine test results/certificate to be providedon deliveryYes/NoYes18.Drawing showing dimensions of the arrestor tobe provided with the bidYes/NoYes19.Minimum one minute wet power frequencywithstand voltage of external insulation of surge arrester housingkV2820.Maximum steep current impulse residualvoltage for a 10 kA, 1/20 µs, discharge currentkV5021.Maximum lightning impulse residual voltagefor a 10 kA, 8/20 µs, discharge currentkV4022.Lightning, 1,2/50 µs, impulse withstand levelof external insulation of surge arrester housingkV9523.Line discharge class rating124.Long duration current, 2 000 µs, impulsewithstandA250 A25.High current, 4/10 µs, impulse withstandkA100 kA26.Automatic earth lead disconnector to be testedin accordance with IEC 60099-4Yes/NoYes33kVS/NTECHNICAL DETAILSUNITSDATA1.Type33kV gapless type metaloxide surge arrester -Distribution class2.Nominal system voltagekV333.Highest system voltagekV364.Power frequencyHz505.Basic Insulation Level (BIL)kV1703. Ratings and type of surge arrester6.Specification to which surge arrester compliesIEC 600997.Rated voltage of surge arresterkV298.Nominal, 8/20 µs, discharge current rating of surge arresterkA109.Maximum continuous operating voltage of surge arresterkV2210.Gapless or gapped type metal-oxide surge arresterGapless11.Insulation MaterialSilicon rubber12.Cantilever strength of surge arresterNm30013.Rated frequency of surge arresterHz5014.Design altitude of surge arrester (above sea level)m1 400m15.Design ambient temperature of surge arresteroC-1 to 4016.Minimum phase-to-ground specific creepage distance ofsurge arrester.mm/kV25Automatic earth lead disconnectors requirements17.Automatic earth lead disconnectors fittedYes/NoYes18.Corrosion protection of metal and alloy parts: galvanisingTo SABS 763, 316specification and/or stainless steel gradeTests19.Previous Type Test reports/certificate from recognizedauthority to be provided with bidYes/NoYes20.Minimum one minute wet power frequency withstandvoltage of external insulation of surge arrester housingkV7021.Maximum steep current impulse residual voltage for a 10kA, 1/20 µs, discharge currentkV99.722.Maximum lightning impulse residual voltage for a 10 kA,8/20 µs, discharge currentkV91.823.Lightning, 1,2/50 µs, impulse withstand level of externalinsulation of surge arrester housingkV17024.Line discharge class ratingClass125.Long duration current, 2 000 µs, impulse withstandA250 A26.High current, 4/10 µs, impulse withstandkA100 kA27.Is the automatic earth lead disconnector tested in accordancewith IEC 60099-4?Yes/NoYes66kVS/NTECHNICAL DETAILSUNITSDATA1.DescriptionStation type lightning arrestorcomplete with steel support structures.2.TypeZinc oxide gapless lightningarrestorSystem parameters3.Nominal system voltagekV664.Highest system voltagekV72.55.Power frequencyHz506.Type of system earthingEffective/Non effective7.Type of arrestor connection to systemLine to ground3. Ratings and type of surge arrester8.Rated voltage of surge arresterkV rms549.Nominal, 8/20 µs, discharge current rating of surge arresterkA peak1010.Maximum continuous operating voltage of surge arresterkV4311.Minimum one minute wet power frequency withstand voltagekVrms140151of external insulation of surge arrester housing12.Maximum steep current impulse residual voltage for a 2 kA,30/60 µs, discharge currentkVpeak10413.Maximum lightning impulse residual voltage for a 10 kA, 8/20µs, discharge currentkVpeak12714.Minimum lightning, 1,2/50 µs, impulse withstand level ofexternal insulation of surge arrester housing32515.Line discharge class rating216.Lighting arrestor counter, leakage current meter and theiraccessories to be providedYes/NoYes17.Gapless or gapped type metal-oxide surge arresterGapless18.Insulation MaterialPorcelain19.Cantilever strength of surge arresterNm300020.Rated frequency of surge arresterHz5021.Maximum angle from vertical at which surge arrester is fullyfunctionalDeg4522.Design altitude of surge arrester (above sea level)m1400 m23.Design ambient temperature of surge arresteroC-1 to 4024.Humidity%8525.Specific phase-to-ground creepage of surge arrester.mm/kV2526.Corrosion protection of metal and alloy parts: galvanisingspecification and/or stainless steel gradeto SABS 763 or 316 stainlesssteel27.Previous type test results/certificate to be provided with bidYes/NoYes28.Design drawings showing dimensions including foundationsand brochures to be provided with bidYes/NoYes29.Quality Assurance certification to be provided with the bidYes/NoYes30.Routine test results/certificate to be provided on deliveryYes/NoYes31.Galvanized steel support structures complete with bolts &washers to be provided on deliveryYes/NoYes32.Applicable standardIEC6009915288KvS/NTECHNICAL DETAILSUNITSDATA33.DescriptionStation type lightning arrestorcomplete with steel support structures.34.TypeZinc oxide gapless lightningarrestorSystem parameters35.Nominal system voltagekV8836.Highest system voltagekV10037.Power frequencyHz5038.Type of system earthingEffective/Non effective39.Type of arrestor connection to systemLine to ground3. Ratings and type of surge arrester40.Rated voltage of surge arresterkV rms8441.Nominal, 8/20 µs, discharge current rating of surge arresterkA peak1042.Maximum continuous operating voltage of surge arresterkV6743.Minimum one minute wet power frequency withstand voltageof external insulation of surge arrester housingkVrms185Maximum steep current impulse residual voltage for a 2 kA,kVpeak18830/60 µs, discharge current45.Maximum lightning impulse residual voltage for a 10 kA, 8/20µs, discharge currentkVpeak21846.Minimum lightning, 1,2/50 µs, impulse withstand level ofexternal insulation of surge arrester housing45047.Line discharge class rating248.Lighting arrestor counter, leakage current meter and theiraccessories to be providedYes/NoYes49.Gapless or gapped type metal-oxide surge arresterGapless50.Insulation MaterialPorcelain51.Cantilever strength of surge arresterNm300052.Rated frequency of surge arresterHz5053.Maximum angle from vertical at which surge arrester is fullyfunctionalDeg4554.Design altitude of surge arrester (above sea level)m1400 m55.Design ambient temperature of surge arresteroC-1 to 4056.Humidity%8557.Specific phase-to-ground creepage of surge arrester.mm/kV2558.Corrosion protection of metal and alloy parts: galvanisingspecification and/or stainless steel gradeto SABS 763 or 316 stainlesssteel59.Previous type test results/certificate to be provided with bidYes/NoYes60.Design drawings showing dimensions including foundationsand brochures to be provided with bidYes/NoYes61.Quality Assurance certification to be provided with the bidYes/NoYes62.Routine test results/certificate to be provided on deliveryYes/NoYes63.Galvanized steel support structures complete with bolts &washers to be provided on deliveryYes/NoYes64.Applicable standardIEC60099
|