Login|Register|Forget password|Dashboard Back to Home|Contact|Shopcart
Unverified1st Year

ORIENT ELECTRIC INTERNATIONAL GROUP LIMITED  

Auto, Motorcycle Parts & Accessories,Construction & Decoration,Electrical & Electronics,Industrial Equipment & Components,Instruments & Meters,Manufacturing & Processing Machinery,Service

Search
新闻中心
  • 暂无新闻
产品分类
  • 暂无分类
联系方式
  • 联系人:Samuel Wong
  • 电话:86-722-7523677
  • 传真:86-722-7523818
站内搜索
 
荣誉资质
  • 暂未上传
友情链接
  • 暂无链接
首页 > Products > Substation Surge Arresters
Substation Surge Arresters
单价 $11.00 / Piece对比
询价 暂无
浏览 149
发货 Chinahubeisuizhou
过期 长期有效
更新 2020-08-18 10:57
 
详细信息
Product Name: Substation Surge Arresters Model NO.: YH10W-132 66KV 72.5KV 275KV Brand: Oeipower Jingguan Certification: Xihari Material: ZnO Shape: Round Operation Voltage: High Voltage Size: Meidum Application: AC/DC System Installation: Pole Line Structure: Zinc Oxide Arrester Type: Distribution Product Description metal oxide surge arrester (MOA) is recognized as the upto-date overvoltage protector which ,due to the inherent superior nonlinear V-A characteristics and steep-wave response of metal oxide varistors ,can suppress overvoltages to a relative low level ,thus providing a reliable protection for insulation of electrical apparatus.The basic technical parameters are complied with the technical specification of IEEE and IEC60099-41. GENERALmetal oxide surge arrester (MOA) is recognized as the upto-date overvoltage protector which ,due to the inherent superior nonlinear V-Acharacteristics and steep-wave response of metal oxide varistors ,can suppress overvoltages to a relative low level ,thus providing a reliableprotection for insulation of electrical apparatus.The basic technical parameters are complied with the technical specification of Chinese Standard GB11032-2000 which is exactly equivalent toIEC60099-42. TECHNICAL DATAZINC OXIDE PROTECTIVE CHARACTERISTICS (5kA NORMAL DUTY POLYMER)VoltageRating(Ur)(kVrms)MCOV(UC)1(kVrms)Max.Equiv.FOW2(kV Crest)Max. SwitchSurge3(kV Crest)Max .Discharge voltage (kV Crest)Using 8/20 s Current Impulse1.5kA2.5 kA 3.0kA5.0 kA 10kA20kA40kA3 2.55 10.0 7.9 8.5 8.8 8.9 9.4 10.2 11.3 13.36 5.10 19.9 15.8 16.9 17.5 17.7 18.8 20.4 22.5 26.69 7.65 29.9 23.7 25.4 26.2 26.6 28.2 30.5 33.8 39.910 8.40 32.9 26.3 28.1 29.2 29.6 31.3 33.9 37.4 43.912 10.20 39.8 31.6 33.8 34.9 35.4 37.6 40.7 45.0 53.115 12.70 49.8 39.5 42.2 43.6 44.3 47.0 50.9 56.3 66.418 15.30 59.7 47.4 50.7 52.3 53.1 56.4 61.0 67.5 79.721 17.00 69.7 55.3 59.1 61.0 62.0 65.7 71.2 78.7 92.924 19.50 79.6 63.2 67.6 69.7 70.8 75.1 81.3 90.0 106.227 22.00 89.6 71.1 76.0 78.4 79.7 84.5 91.5 101.2 119.530 24.40 99.5 78.8 84.2 87.4 88.7 93.9 101.7 112.0 131.733 26.80 109.5 86.7 92.6 96.2 97.6 103.3 111.9 123.2 114.936 30.00 119.4 94.6 101.0 104.9 106.4 112.7 122.0 134.4 158.0High-Current Short Duration: 2 current surges of 65kA magnitude and 4/10s wave shape.Low-Current Long Duration : 20 current surges of 75 A magnitude and 2000s duration .1 MCOV=Maximum Continuous Operating Voltage that may be applied continuously between the terminals of the arrester.2 The equivalent Front-of -Wave is the maximum discharge voltage for a 5kA impulse current wave which produces a voltage wave cresting in0.35s.3 based on a switching surge current impulse of 45×90s, 500 amperes.4 The equivalent Front-of-Wave is the maximum discharge voltage for a 10kA impulse current wave which produces a voltage wave cresting in0.5s.23.APPLICATION CONDITION3.1 Normal Service conditionSurge arresters which conform to this standard shall be suitable for normal operation under the following normal service conditions:Ambient air temperature within the range of -40 to +40.Solar radiation :The effects of maximum solar radiation (1.1kW/m2)have been taken into account by preheating the test specimen in the type tests. If there areother heat sources near the arrester, the application of the arrester shall be subject to an agreement between the manufacturer and thepurchaser.Altitude is not exceeding 1000m.Frequency of the A.C power supply is not less than 48Hz but not more than 62HZ.Power frequency voltage applied continuously between the terminals of the arrester is not exceeding its continuous operating voltage.Mechanical conditions ;no strong vibration.Pollution conditions: no requirement at this time.